Solutions / Fire performance
Fire behaviour is a property of the system, not of the additive.
Wood species, panel structure, treatment level, geometry, later coatings and the test standard all change the result. We therefore work on a defined build-up, test it, and tie every statement to that test.
What we have measured
D-s1,d0 C-s1,d0
Preliminary Single Burning Item test to EN 13501-1. Three-layer spruce. TÜV SÜD, 03/2025. The class applies to this tested build-up only.
The first test: a flame on thin fir.
Berner Fachhochschule, 02/2024. A flame was held to the lower edge of each specimen for 30 seconds.
- Treated specimens thicker than 4 mm did not ignite. All untreated control specimens did.
- Treated specimens under 3 mm burned only while the flame touched them, then went out by themselves.
- The thicker treated specimens lost very little weight.
Fir, untreated


Fir, impregnated with PURE B210




Where it applies
- Solid wood and timber elements
- Engineered wood products
- Natural-fibre and biomass boards
- Insulation and acoustic materials
What is still open
- Smoke production rose in the SBI test. The formulation is being adapted.
- The SBI result is preliminary and covers one build-up of three-layer spruce.
- A classification for your product needs a test on your product.
The usual way in is a Validate programme on your own substrate.